OLDI-Tools

PDF Version

- the Si ATM OLDI Simulation, Shadowing and Monitoring Systems

NEW FMTP HANDLING!

OLDI-Tools now also handles FMTP and supports transition between
old FDE-ICD format (X.25) to FMTP (TCP/IP) by acting as a gateway
between “old” and “new” systems in a mixed environment where some
are adapted to FMTP and some not.
Hence, the system is a part of the operational system but still is used for
testing and monitoring as before.

On-Line Data Interchange (OLDI)  is a standard defined by EUROCONTROL to handle flights which are being provided with an ATC service to be transferred from one ATC unit to the next in a manner designed to ensure complete safety. This is accomplished with the OLDI standard procedure that the passage of each flight across the boundary of the areas of responsibility of the two units is co-ordinated between them beforehand and that the control of the flight is transferred when it is at, or adjacent to, the said boundary.

The OLDI-Tools is a testing tool to facilitate an efficiant and safe implementation of OLDI.

”"

Usage of OLDI-Tools

The OLDI-Tools is used for:

  • OLDI testing in new ACC systems before taken into operational use
  • OLDI testing in an TDS (Test and Development System) environment
  • OLDI monitoring in an operational environment
  • Testing new OLDI partners

System concept

The system consists of two major parts, the OLDI-MON system and the OLDI-SIM system. The purpose with OLDI-SIM is to supply a “new”system under test with simulated OLDI messages and/or “real” OLDI messages, depicting real traffic in an “old” system, in order to test new SW releases, new OLDI lines, etc.

The purpose with OLDI-MON is to supply OLDI-SIM with “real” OLDI messages, representing real traffic in the currently operational system. The design of this system is more or less site dependant. OLDI-MON is also used for monitoring OLDI communication in the operational ACC system for maintenance and logging purposes.

OLDI-Tools modes of operation

Shadow mode

  • The live OLDI traffic is monitored and distributed to OLDI-SIM in order to achieve a realistic test scenario in the “new” system

Simulation mode

  • The OLDI connection is simulated by OLDI-SIM

Monitoring mode

  • OLDI communication real time monitoring on all protocol levels including logging and recording facilities is performed by OLDI-MON

Handled messages

The following OLDI messages are handled: ABI, ACT, PAC, MAC, REV, COF, MAS, LAM. OLDI messages can be manually handled through an Operator window or automatically through a Scenario window.

Manual Operator functionality:

  • Create and store OLDI messages
  • Edit stored messages
  • Send messages
  • Select format
  • Preview messages
  • Import messages from log file

Scenario functionality:

  • Automatically send predefined messages
  • Scenarios control, scenarios can be paused, restarted or stopped
  • Messages handling, OLDI messages can be created/changed or removed
  • Messages are sent with an offset time from each other
  • Result display, all sent or revecied messages are displayed with related errors messages if any
  • Statistics,  message counts for sent/received messages